The essentials in 30 seconds
Spray polyurethane foam (SPF) is made on site by mixing two liquids that react, expand and harden. Open-cell foam is soft and light, gives about R-3.6 per inch and lets water vapor pass. Closed-cell foam is rigid and dense, gives about R-6 per inch and acts as a vapor retarder at typical thickness. Both are excellent at air sealing. The chemicals, especially isocyanates, can cause asthma and sensitization, so the US Environmental Protection Agency (EPA) says occupants should leave during installation and stay out until the manufacturer's re-occupancy time has passed and the space has been ventilated and cleaned.
- Below grade (basements, crawl spaces), the Department of Energy (DOE) guidance favors closed-cell and rules out open-cell.
- Spray foam is hard to remove later; EPA knows of no standard accepted removal practice.
- In the UK, some mortgage lenders and surveyors are wary of spray foam in lofts, so get independent advice first.
What spray foam insulation is and the product types
Spray foam starts as two liquids. The A side contains isocyanates (in building foam, usually polymeric MDI). The B side is a polyol blend with catalysts, flame retardants, blowing agents and surfactants. They meet at the spray gun, react with heat, expand and set into foam that fills gaps, cracks and voids.
| Type | Typical use | Who should use it |
|---|---|---|
| Two-component high-pressure | Whole walls, roof decks, attics and larger insulation jobs | Professional installers only; sprayed hot and at high pressure, with supplied-air respirators |
| Two-component low-pressure kit | Air sealing and smaller insulation jobs | Professionals and weatherization crews; sold to DIY users too, but EPA notes they often underestimate the breathing and skin hazards |
| One-component can | Sealing cracks and gaps around windows, doors and pipes | Anyone, with the same precautions as a professional; some manufacturers estimate 8 to 24 hours to cure |
Open-cell vs closed-cell spray foam
The two foams are chemically similar but behave so differently that DOE's Building America guidance treats them as separate products that are not interchangeable.
| Property | Open-cell | Closed-cell |
|---|---|---|
| Density | About 0.5 lb per cubic foot ("half-pound foam") | About 2 lb per cubic foot ("2-lb foam") |
| R-value per inch | About R-3.6 | About R-6 |
| Expansion | About 150 times its liquid volume; can be sprayed up to about 10 inches in one pass | About 35 to 50 times; sprayed in 2 to 3 inch layers |
| Air sealing | Air-impermeable at typical thickness | Air-impermeable at typical thickness |
| Water vapor | Lets vapor through: about 5 to 10 perms at 5 inches | A vapor retarder: under 1 perm at 2 inches |
| Liquid water | Absorbs and holds water, up to about one-third of its volume | Repels water |
| Feel and strength | Soft, compressible | Rigid; adds stiffness to framing and roof decks |
A vapor retarder is defined as 1 perm or less, so open-cell foam is not one. That single fact drives most of the decisions below.
Where each type of spray foam works best
DOE's Building America guide rates each foam for common locations. A summary:
| Location | Open-cell | Closed-cell |
|---|---|---|
| Rim joists (band joists) and sill plates | Acceptable | Preferred, especially in hot-humid or very cold climates |
| Basement walls and crawl spaces | Not acceptable: it soaks up water from the ground | Preferred, against the foundation wall |
| Underside of the roof deck (unvented attic, cathedral ceiling) | Acceptable, with vapor control in cold climates | Preferred in all climates |
| Wall cavities, cold climates | Preferred, with interior air sealing and vapor control | Preferred, alone or as a "flash" coat under batts |
| Wall cavities, hot-humid climates | Acceptable, with careful rain and vapor control | Preferred |
| Floor of a vented attic | Rarely used; R-value per inch is close to loose-fill | Thin coat for air sealing, then loose-fill on top |
For the floor of a vented attic, blowing loose-fill over a well-sealed ceiling is the usual approach: see blown-in insulation and attic insulation. For crawl spaces, read crawl space encapsulation.
Flash-and-batt is a common hybrid: a thin layer of closed-cell foam against the sheathing for air and vapor control, with batts or loose-fill filling the rest of the cavity. DOE's guide recommends at least 1½ inches of closed-cell in this setup in cold climates, and at least 2 inches in climates above 6,000 heating degree days, so the inner face of the foam stays warm enough to avoid condensation.
Air sealing, moisture and vapor: getting it right
Spray foam's strength is stopping air leaks, which other insulation lets through. Its risk is moisture trapped in the wrong place. Points from DOE's guide:
- Open-cell in cold climates needs interior air sealing and a vapor retarder at the finished surface, such as vapor-retarder primer. DOE cites a reported failure in northern Vermont where open-cell walls had neither, behind an exterior that could not dry.
- Closed-cell in hot-humid climates: avoid adding a plastic vapor barrier on the inside, or moisture can be trapped between two barriers.
- Roofs: with closed-cell foam on the roof deck, a slow roof leak may go unnoticed because water cannot pass through the foam. Fix any roof leak before foaming and keep an eye on the roof afterwards.
- Open-cell under a roof gets wet when the roof leaks, then dries out slowly once the leak is fixed.
In the UK, spray foam in lofts has caused difficulties for homeowners: a Scottish Parliament briefing notes that some lenders refuse mortgages or equity release where it is present, and that foam can hide problems from surveyors and block ventilation if installed badly.
Fire safety and building code
Both foams are combustible. Building codes in the US generally require spray foam in living spaces to be covered by a 15-minute thermal barrier, which DOE's guide equates to ½-inch gypsum board. In attics and crawl spaces entered only for servicing, an ignition barrier may be enough, or exposed foam may be allowed if that exact product has been tested for it. Ask the contractor for the product's evaluation report and how they will meet the barrier rule in your space.
Health and safety during and after installation
EPA's guidance for homeowners, step by step:
-
01
Before the day
Ask the contractor and the manufacturer for the ventilation time, re-entry time and re-occupancy time for this product. Some manufacturers recommend 24 hours for professional two-component foam, but times vary.
-
02
Plan to be away
Everyone without protective gear leaves during spraying, including children, pets and other trades. Children are especially vulnerable because they play close to floors where dust and residue settle.
-
03
Seal the work area
The crew should shut down the heating and cooling system and seal vents so vapors stay out of the rest of the house.
-
04
Let it cure fully
Foam can look hard while still curing. Temperature, humidity, thickness and mixing all affect cure time.
-
05
Ventilate and clean
Re-entry should wait until the foam has cured and the area has been ventilated and thoroughly cleaned.
-
06
Check for problems
Strong lingering odors or symptoms are a reason to call the contractor back. If that does not resolve it, contact an independent indoor air quality consultant, your state consumer protection office or contractor licensing board, and report it to the CPSC at SaferProducts.gov.
Cured foam is considered relatively inert. The risks come back when it is drilled, sanded, ground, heated or burned, so tell any electrician, plumber or builder working near it, and find out whether a house has spray foam before renovating.
DIY spray foam kits vs hiring a professional
- Cans of one-component foam are fine for sealing small gaps around pipes, wires and window frames. Use eye protection, nitrile gloves and good ventilation, keep cans away from children, and let the foam cure before trimming it.
- Low-pressure two-component kits are sold for small jobs such as a few rim joist bays. EPA calls for full skin coverage, eye protection, chemical-resistant gloves and a properly fitted respirator, and warns that DIY users often underestimate these hazards. Mixing errors also slow curing and can leave odors.
- High-pressure rigs are for trained professionals only.
For whole attics, roof decks and walls, hire a professional and ask:
- Which product, open- or closed-cell, and what thickness and R-value will I get?
- How will you handle vapor control for my climate and this location?
- How will the foam meet the thermal or ignition barrier requirement?
- What is the re-occupancy time, and how will you ventilate and clean before we return?
- What training has the crew completed, and what paperwork will you leave? In the UK, the briefing advises keeping test certificates, contracts and guarantees for when you sell.
When spray foam is a poor choice
- Open-cell foam below grade, in basements or crawl spaces.
- Anyone in the home has asthma or a known isocyanate sensitivity, and alternatives would do the job.
- The roof leaks or the timbers need checking: fix and inspect first, because foam hides the deck.
- A simple attic top-up: loose-fill over a sealed attic floor is usually the straightforward answer.
- You may need to remove it later: EPA notes that removal may fail to solve a problem and can create new ones.
- The attic has vermiculite: leave it undisturbed and read asbestos testing first.
Spray foam insulation: frequently asked questions
What is the difference between open-cell and closed-cell spray foam?
Open-cell is soft, about R-3.6 per inch and lets vapor through. Closed-cell is rigid, about R-6 per inch and acts as a vapor retarder.
Is spray foam insulation safe?
Cured foam is considered relatively inert, but the chemicals are hazardous during spraying and curing. Stay out until the manufacturer's re-occupancy time has passed and the space is ventilated and cleaned.
How long after spray foam can I go back in the house?
It depends on the product. Some manufacturers recommend 24 hours for professional foam; ask for the exact time in writing.
Can spray foam cause health problems?
Isocyanate exposure can cause skin, eye and lung irritation, sensitization and asthma. Seek medical attention if anyone has breathing problems.
Can I use spray foam in a basement?
Closed-cell, yes: DOE's guide prefers it against foundation walls. Open-cell is unsuitable below grade because it absorbs water.
Is spray foam good for an attic?
On the underside of the roof deck it can create a sealed attic. On the attic floor, loose-fill over a sealed ceiling is usually the simpler choice.
Can I spray foam insulation myself?
Cans for small gaps, yes, with care. Two-component kits need full protective gear, and large jobs are best left to trained installers.
Why do UK lenders worry about spray foam?
Foam on loft rafters can hide the condition of the timbers, and some lenders refuse mortgages where it is present. Get independent advice before installing it.
Sources
Official guidance on spray foam, checked on 27 October 2026.
- US DOE Building America · Which spray foam is right for you? ↗Density, R-value per inch, expansion, vapor permeance, water absorption, fire barriers and where each foam fits.
- US EPA · Spray polyurethane foam product types ↗High-pressure, low-pressure and one-component products, protective equipment and chemistry.
- US EPA · Vacate and safe re-entry time for spray foam application ↗Leaving during installation, re-occupancy, cure times, children and where to report problems.
- US EPA · Health concerns about spray polyurethane foam ↗Isocyanates, sensitization, asthma and who is most at risk.
- US EPA · Potential chemical exposures from spray polyurethane foam ↗Exposure during and after installation, heating or sanding cured foam, odors and removal.
- Scottish Parliament Information Centre · The use of spray foam insulation in Scotland ↗UK lender concerns, roof inspection, ventilation and keeping paperwork.
Comparing spray foam quotes?
Ask each contractor for the product name, thickness, vapor plan and re-occupancy time in writing.